Single Use Conductivity Sensors

PendoTECH

PendoTECH’s Single-Use Conductivity Sensors™ and Conductivity Monitor are used for highly accurate conductivity and temperature measurements without the need for sensor calibration. All sensors have a pre-determined cell constant which is entered into the moni Read More ...

PendoTECH’s Single-Use Conductivity Sensors™ and Conductivity Monitor are used for highly accurate conductivity and temperature measurements without the need for sensor calibration. All sensors have a pre-determined cell constant which is entered into the monitor. The sensor monitor reads conductivity and temperature for two sensors. The monitor has a mS/cm temperature adjustment value that normalizes conductivity readings to 25°C. Additionally, it has 4–20mA outputs for both conductivity and temperature that can transmit the readings to a higher level control system such as a PLC or DeltaV and an RS-232 output for data collection to a PC.

Sensor Details:

• Measure conductivity and temperature

- Conductivity Range: 0.1 to 100mS/cm

- Temperature Range: 2°C to 50°C

• Fluid path materials

- Gamma & X-ray irradiation compatible

- NaOH resistant

- USP Class VI

• Temperature measurement used by the monitor to perform normalization to 25°C

• No calibration required because of pre-determined cell constant and also optional one-point calibration by user

• Low cost for single use applications; may be repeatedly cleaned and re-used

Read Less

CATEGORIES: Fluid Handling

Catalog Number Product Name Action
CONDS-N-012 Single Use Conductivity Sensor, non-sterile, polysulphone, 1/8 inch hose barb
CONDS-N-025 Single Use Conductivity Sensor, non-sterile, polysulphone, 1/4 inch hose barb
CONDS-N-050 Single Use Conductivity Sensor, non-sterile, polysulphone, 1/2 inch hose barb

Single Use Conductivity Sensors

PendoTECH

PendoTECH’s Single-Use Conductivity Sensors™ and Conductivity Monitor are used for highly accurate conductivity and temperature measurements without the need for sensor calibration. All sensors have a pre-determined cell constant which is entered into the monitor. The sensor monitor reads conductivity and temperature for two sensors. The monitor has a mS/cm temperature adjustment value that normalizes conductivity readings to 25°C. Additionally, it has 4–20mA outputs for both conductivity and temperature that can transmit the readings to a higher level control system such as a PLC or DeltaV and an RS-232 output for data collection to a PC.

Sensor Details:

• Measure conductivity and temperature

- Conductivity Range: 0.1 to 100mS/cm

- Temperature Range: 2°C to 50°C

• Fluid path materials

- Gamma & X-ray irradiation compatible

- NaOH resistant

- USP Class VI

• Temperature measurement used by the monitor to perform normalization to 25°C

• No calibration required because of pre-determined cell constant and also optional one-point calibration by user

• Low cost for single use applications; may be repeatedly cleaned and re-used

CATEGORIES: Fluid Handling

Catalog Number Product Name
CONDS-N-012 Single Use Conductivity Sensor, non-sterile, polysulphone, 1/8 inch hose barb
CONDS-N-025 Single Use Conductivity Sensor, non-sterile, polysulphone, 1/4 inch hose barb
CONDS-N-050 Single Use Conductivity Sensor, non-sterile, polysulphone, 1/2 inch hose barb