Single Use Conductivity Sensors
PendoTECH
PendoTECH’s Single-Use Conductivity Sensors™ and Conductivity Monitor are used for highly accurate conductivity and temperature measurements without the need for sensor calibration. All sensors have a pre-determined cell constant which is entered into the moni Read More ...
PendoTECH’s Single-Use Conductivity Sensors™ and Conductivity Monitor are used for highly accurate conductivity and temperature measurements without the need for sensor calibration. All sensors have a pre-determined cell constant which is entered into the monitor. The sensor monitor reads conductivity and temperature for two sensors. The monitor has a mS/cm temperature adjustment value that normalizes conductivity readings to 25°C. Additionally, it has 4–20mA outputs for both conductivity and temperature that can transmit the readings to a higher level control system such as a PLC or DeltaV and an RS-232 output for data collection to a PC.
Sensor Details:
• Measure conductivity and temperature
- Conductivity Range: 0.1 to 100mS/cm
- Temperature Range: 2°C to 50°C
• Fluid path materials
- Gamma & X-ray irradiation compatible
- NaOH resistant
- USP Class VI
• Temperature measurement used by the monitor to perform normalization to 25°C
• No calibration required because of pre-determined cell constant and also optional one-point calibration by user
• Low cost for single use applications; may be repeatedly cleaned and re-used
Read LessCATEGORIES: Fluid Handling
Catalog Number | Product Name | Action |
---|---|---|
CONDS-N-012 | Single Use Conductivity Sensor, non-sterile, polysulphone, 1/8 inch hose barb | |
CONDS-N-025 | Single Use Conductivity Sensor, non-sterile, polysulphone, 1/4 inch hose barb | |
CONDS-N-050 | Single Use Conductivity Sensor, non-sterile, polysulphone, 1/2 inch hose barb |
Single Use Conductivity Sensors
PendoTECH
PendoTECH’s Single-Use Conductivity Sensors™ and Conductivity Monitor are used for highly accurate conductivity and temperature measurements without the need for sensor calibration. All sensors have a pre-determined cell constant which is entered into the monitor. The sensor monitor reads conductivity and temperature for two sensors. The monitor has a mS/cm temperature adjustment value that normalizes conductivity readings to 25°C. Additionally, it has 4–20mA outputs for both conductivity and temperature that can transmit the readings to a higher level control system such as a PLC or DeltaV and an RS-232 output for data collection to a PC.
Sensor Details:
• Measure conductivity and temperature
- Conductivity Range: 0.1 to 100mS/cm
- Temperature Range: 2°C to 50°C
• Fluid path materials
- Gamma & X-ray irradiation compatible
- NaOH resistant
- USP Class VI
• Temperature measurement used by the monitor to perform normalization to 25°C
• No calibration required because of pre-determined cell constant and also optional one-point calibration by user
• Low cost for single use applications; may be repeatedly cleaned and re-used
CATEGORIES: Fluid Handling
Catalog Number | Product Name |
---|---|
CONDS-N-012 | Single Use Conductivity Sensor, non-sterile, polysulphone, 1/8 inch hose barb |
CONDS-N-025 | Single Use Conductivity Sensor, non-sterile, polysulphone, 1/4 inch hose barb |
CONDS-N-050 | Single Use Conductivity Sensor, non-sterile, polysulphone, 1/2 inch hose barb |