MAS-100 NT Validation protocol
Catalog Number: MANTA4VP2
Pack Size: 1 no
Brand: Merck
The MAS-100 NT® microbial air monitoring systems are high performance, portable, battery operated instrument which are based on the principle of the Andersen air sampler. These compact yet sophisticated devices are the preferred choice for those demanding the highest quality in microbial air monitoring. A specified amount of air is aspirated through a 300-hole x 0.6 mm perforated lid and impacted onto the surface of growth media in standard 90-100 mm Petri dishes. All functions and parameters as well as the calibration procedure can be controlled using the MAS-100 NT® software or may be programmed directly on the unit. Alarms and samples are logged and the last 100 events recorded. These can be exported or printed at any time. Hardware and software have been developed according to GAMP4.
Application
The MAS-100 NT® air sampler is used for microbial monitoring of ambient air in controlled environments up to ISO 5 cleanrooms. Microbial air sampling devices are extensively used in Pharmaceutical and Personal care industries as well as Food, Beverage and Environmental applications. Additionally, a regulation for compounding pharmacies, USP797, that requires active air sampling in the level 5 and above areas.
Benefits:
SKU : 1.09191.0001
PACK SIZE : Pack 1
CATEGORIES : Environmental Monitoring
Height | 179 mm |
---|---|
Diameter | 109 mm |
Depth with handle | 148 mm |
Weight | 1.75 kg (with sampling head) |
Material | Anodized aluminum |
Diameter of Sampling head | 10 cm |
Nominal Airflow | 100 LPM ± 4.0% |
Sampling Volume | Preset values: 50, 100, 250, 500 and 1000 liters. Each volume can be preset to a value from 1-1.000 liters |
Airflow regulation | Electronic |
Petri dish support | For standard Petri dishes and Contact plates |
Tripod screw | 1/4"and 3/8” for use with optional tripod |
Rechargeable batteries | Rechargeable Li-ion battery pack |
Motor | 6 V |
Display | Alphanumeric liquid crystal display, 2 x 8 characters |
RTC Battery | RTC (Real Time Clock) battery; Lifetime: Approximately 10 years |
Operating conditions | Temperatures 5 to 40° C, humidity 0 to 80% RH (non-condensing) |
Control unit | Microprocessor |
CE Approval | Emission: EN 61326:1997/A1:1998, EN 55022:1998 +A1:00. Immunity: EN 61326-1:1997/A1:1998, EN 61000-4-2:1995. +A1:98 +A2:01, EN 61000-4-3:1998 +A1:98. +A2:01, EN 61000-4-4:1995 +A1:01 +A2:01, EN 61000-4-5:1995 +A1:01, EN 61000-4-6:1996 +A1:01, EN 61000-4-8:1993 +A1:01, EN 61000-4-11:1994+A1:98 +A2:01. |
Power Unit / Battery Charger | 110 to 240 V, 47-63 Hz |
Output | 5V DC/2000 mA |